  • Adjust speed 1 to 300 SPM plus stroke length adjustment..
  • sizes -31/ -61/ -12: 50% to 100% stroke length adjustment,
  • sizes -32/ -52 plus all PZD and PZiG Models: 20% to 100% stroke length adjustment..
  • Enter desired flow directly in ml/min..
  • Calibrate pump flow to actual condition of chemical,pressure, viscosity, etc...
  • External interlock (Examples: level switch, remote start, reset)..
  • Indicates speed and status..
  • Indicates speed, feed rate2, status and other operational data..
  • Pulse signal Frequency-divide 1/1 to 1/9999, Multiply 1 to 9999..
  • Analog signal Shift function, Proportional band function..
  • pH Control/Residual Chlorine Control..
  • PZi8 and PZiG have one analog input and two high speed digital pulse inputs..
  • Alarm output (Level switch, injection monitor..
  • PZi8 only when used with Flow Checker..
  • Operation pulse signal (Synchronous pulse output for each stroke)..
  • Operation progress signal (Time or number of strokes remaining in program)..
  • Two separate configurable outputs, either open collector (alarm, error, run) or pulse (operational sync or end of cycle)...
  • Alarm display, output and action (run, pause or stop) can be selected..
  • Two point level control.. Power supply for flow checker..
  • Interval operation (Repeat cycle program,ON time: 1 to 999999 minutes / OFF time: 1 to 999999 minutes..
  • Counter (Countdown batch injection,1 to 9999 strokes (X1, X10, X100, X1000)..
  • Head can be turned 90° to allow base to be mounted to a vertical wall..
  • Sizes -31/ -61/ -12 only.

Discontinued See PW Model

CAUTION – ALL MODELS • Ambient temperature: 32 to 104°F (0 to 40°C) Pumped liquids: Temperature: 32 to 104°F (0 to 40°C), Viscosity: 100 CPS max. except as noted • This pump is designed for outdoor use. Avoid installing pump in a location where service life could be shortened (i.e., where it is exposed to direct sunlight or driving rain). • This pump cannot pump liquids containing a slurry. • A relief valve should be installed on the discharge side, if the pump does not have a built-in relief valve and the discharge piping has a shutoff valve..

1 - 15 of 15 | Results Per Page | View |
1 

Item #

Item Name

Add To Cart/Request Quote
N/A 10.5gal/dy(0.44)gal/hr 220psi Kynar (EPDM) Add To Cart
Request Quote
N/A 10.5gal/dy(0.44)gal/hr 220psi 316SS (EPDM) Add To Cart
Request Quote
N/A 11.4gal/dy(0.48)gal/hr 140psi PVC (EPDM) Add To Cart
Request Quote
N/A 11.4gal/dy(0.48)gal/hr 140psi PVC (Viton) Add To Cart
Request Quote
N/A 11.4gal/dy(0.48)gal/hr 140psi Acrylic (Viton) Add To Cart
Request Quote
N/A 11.4gal/dy(0.48)gal/hr 140psi Acrylic (Viton) Add To Cart
Request Quote
N/A 11.4gal/dy(0.48)gal/hr 140psi Kynar (Viton) Add To Cart
Request Quote
N/A 11.4gal/dy(0.48)gal/hr 140psi Kynar(PTFE) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi Kynar(PTFE) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi PVC (Viton) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi PVC (EPDM) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi Acrylic (Viton) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi Acrylic (Viton) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi Kynar (Viton) Add To Cart
Request Quote
N/A 22.8gal/dy(0.95)gal/hr 115psi 316SS (EPDM) Add To Cart
Request Quote