• Product Image- 5075 Totalizing Monitor

    3-5075 198825007 Discontinued - No Longer Available        (See 9900 Transmitter)

    http://products.uscosupply.com/category/ss-controls-gf-signet-multi-parameter-instruments-

    The 5075 Totalizing Monitor is designed for simple flow totalization and flow rate. It is compatible with all +GF+ SIGNET flow sensors. The 5075 is independently calibrated, and measures virtually any volumetric unit from ml to acre-feet. Independently calibrated flow and totalizer displays. Scalable pulse outputs. Two 8-digit totalizers; resettable and non-resettable. Backlit Liquid Crystal Display with High Visibility Analog Indication.

    • Display:
      • Analog: Slide in dials 0-2, 4, 6, 8, 10, 100
      • Digital: Backlit 2 x 16 character alphanumeric LCD
    • Power Requirements: 12 to 24 VAC or 12 to 24 VDC, unregulated, 50-0 Hz, 10W max.
    • Immunity: EN50082-2
    • Emissions: EN55011
    • Safety: EN61010-1

  • Product Image- 5090 Sensor Powered Flow Monitor

    The most economical flow monitor in the SIGNET product line is also one of the most feature-packed. The 5090 Sensor Powered Flow Monitor is designed exclusively for use with the SIGNET 515 Rotor-X Flow Sensor to provide a completely independent flow monitoring system. The combination is FM approved for hazardous environments (has been discontinued), No other indicator or rotameter provides the application versatility and the unique.

    • Accuracy: ± 2% of full scale
    • Repeatability: ± 1% of full scale
    • Operating temperature: 14° F to 149°F
    • Dials: Reversible dial kit included (0-2, 4, 6, 8, 10, 100)

  • Product Image- 5500 Flow Monitor

    Discontinued - No Longer Available      (See 9900 Transmitter)

    The SIGNET 5500 Flow Monitor is a feature-packed process monitor covering the widest possible spectrum of applications. Dual totalizers are calibrated independently of the digital analog flow rate. Reset one totalizer remotely from 100 feet away. Expand the communication range of the system by connecting peripheral equipment to the isolated frequency out, the totalizer pulse output, the alarm contact outputs, or the 4-20 mA current output. Packaged in a slim-line housing with NEMA 4X shatterresistant front panel. Simple pushbutton operation Independently calibrated flow and totalizer displays.

    • Accuracy: ±0.5% of reading
    • Repeatability: ±0.2% of reading.
    • Power Requirements: 12 to 24 VAC or 12 to 24 VDC, unregulated, 50-60 Hz, 10W max.
    • Display:
      • Totalizers: 8-digit resettable with security option 8-digit non-resettable.
      • Operating Temp: max. 122°F with optional rear cover.
    • Alarm contacts:
      • Two SPDT relays: 5A at 30 VDC max., 5A at 125 VAC, or 3A at 250 VAC
      • HI/ LO/ Pulse programmable with adjustable Hysteresis.
      • Accuracy: ±0.1%

  • Product Image- 5600 Batch Monitor

    Discontinued - No Longer Available    (See 9900 Transmitter)

    The +GF+SIGNET 5600 Batch Controller was designed specifically for simple, single function batching systems. A user-selectable menu allows easy configuration of current and relay options. One relay provides batch in-progress alarming and the other can be used for a two stage shutdown, overrun alarm, end-of-batch or missing signal alarm. The 5600 can be combined with any +GF+ SIGNET flow sensor and an appropriate actuator valve/positioner for automated batching. Backlit LCD. User friendly menu with simple setup and operation. Easy changeability of batch size. Remote and “daisy-chain” capabilities.

    • Power Requirements: 12 to 24 VAC or 12 to 24 VDC, unregulated, 50-60 Hz, 10W max.
    • Display:
      • Analog: Reversible dial, 0 to 100% or 100 to 0%
      • Batch size: 0 to 999999 engineering units
      • Totalizer: 8-digit resettable and non-resettable
    • Current Output:
      • 4 to 20 mA, non-isolated, internally powered
      • Accuracy: ±0.1%
    • Alarm Contacts:
      • Two SPDT relays: 5A at 30 VDC max., 5A at 125 VAC, or 3A at 250 VAC
      • Option: Two-stage shutdown, overrun alarm, end of batch pulse, missing signal alarm remote start, stop, resume
      • Operating temperature: 14 to 131oF Accuracy: ±0.5% of reading
    • Enclosure: ABS Plastic, NEMA 4X/IP65

  • Product Image- 8150 Battery Powered Flow Monitor

    The +GF+ SIGNET 8150 Battery Operated Flow Totalizer is compatible with the+GF+SIGNET 515, 525 and 2517 flow sensors, and will provide years of dependable operation. One of the three totalizers is resettable from the front panel or a remote location, while the second resettable totalizer can only be reset by entering a user-selectable security code. Meanwhile, the third is a permanent non-resettable totalizer. Our intuitive software design and four-button keypad provide for simple operation while setting screen displays and programming the system. A display averaging feature is included for applications where the flow in the pipe fluctuates, for applications where flow stops and starts due to production needs, a no-flow indicator will display the hours of non-flow. An optional splash proof rear cover can be ordered separately if needed.

    • Three totalizers
    • Long-lasting lithium batteries.
    • Mounting versatility.
    • No-flow indicator.
    • Large digital display with averaging.
    • Simple push-button operation.
    • User selectable access code prevents unwanted changes.
    • Auto-calibration.

  • Product Image- 8550 Flow Transmitter

    Discontinued - No Longer Available        (See 9900 Transmitter)

    The +GF+ SIGNET 8550 Flow Transmitter is an advanced solution that converts the signal from all +GF+ SIGNET flow sensors into a 4 to 20 mA signal for long distance transmission. Configuration flexibility is maximized with two optional relays for process control, two packaging options for integral/pipe mount or panel installation, and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability, signal stability, and simple user setup and operation.

    • Accuracy: ±0.5 Hz.
    • Enclosure: Rating NEMA 4XIP65 front CSA, CE, UL listed
    • Manufactured under ISO 9001.
    • Sensor power:
      • 2-wire: 1.5 mA at 5 VDC ±1%
      • 3- or 4-wire: 20mA at 5 VDC ±1%.
    • Current output:
      • 4 to 20 mA, isolated, fully adjustable and reversible
      • Power: 12 to 24 VDC ±10%, regulated
      • Accuracy: ±0.03 mA.
    • Relay output:
      • Mechanical SPDT contacts: Hi, Lo, Pulse, Off
      • Maximum voltage rating: 5 A at 30 VDC, 5 A at 250 VAC resistive load.
      • Hysteresis: User adjustable,
      • Open-collector output: Hi, Lo, Pulse, Off.
      • Open-collector, optically isolated, 50 mA max, sink, 30 VDC max. pull-up voltage.

  • geoRotameterGroup

    Vertical flow meters used to measure the rate of flow of liquids or gases in industrial piping systems. Wide selection of materials and measurement scales allows rotameters to be used in a broad range of applications and media. UPW models are also available for applications that require ultra-pure conditions.

    • End connections from 3/8" to 2-1/2" (socket, threaded and flanged) in PVC, PP and PVDF
    • Tubes available in Polyamide (PA) and Polysulphone (PSU)
    • Scales available in GPM, LPH, Percentage (10-100%), SCFM and m3/h.
    • Accuracy 3% of full scale; 1% of measured range
    • Rated pressure 150 psi at 68°F
    • Rated Temperature 32°-140°F (PA and PSU with PVC ends); 32°-194°F (PSU with PP ends); 32°-212°F (PSU with PVDF ends)
    • Seal materials in EPDM or FPM

  • sigPortaflowImage

    The Portaflow range brings simplicity to the non-invasive measurement of liquid flow. Portaflow offers the user quick and accurate flow measurement with its easy to follow menu and simple set up. Results can be achieved within minutes of opening the case. Compact, rugged and reliable, the Portaflow range has been designed to provide sustained performance in industrial environments.
    Features

    • Large, easy to read graphic display with backlighting
    • Easy to install thanks to flexible guide rails
    • Rechargeable battery for up to 20 hours mobile operation
    • Simple to follow dual function keypad
    • Simple ‘Quick Start’ set up procedure
    • Data logger for 198k data points (Type PF330)
    • Analog and pulse outputs