• GPITM50

    This economy water flow meter is an ideal alternative to traditional water meters. The TM Series water meters offer flow rate and flow total indication that help monitor water flow in wastewater application, water treatment, and sub-metring application. The battery powered electronic display TM Series water flow meters are calibrated to read in gallons and liters per minute. These water flow meters also have two totals in which case one is resettable and the other gives you cumulative flow totals. These electronic water meters are available in 1/2 inch, 3/4 inch, 1 inch, 1-1/2 inch and 2 inch models.

    Flow Meters for use with:

    • Water Irrigation Systems
    • Sub-Metering Applications
    • Waste Water Treatment

  • Product Image- Electronic Digital Water and Fuel Meters

    This meter easily installs either inline or at the end of the hose. The large, easy-to-read display and compact, lightweight design please any user. A rugged nylon housing and sealed electronic circuitry provides years of durable use in almost any condition. Two AAA batteries power the small microprocessor for a year and are very easy to replace.

    Calibrated at the factory to accurately measure water. No user calibration available.
    Works well on any pump, pressure, or gravity feed system with at least 3 to 30 GPM (10 to 100 LPM) flow range.

  • gpi03N

    Easy to use, describes these lightweight and compact meters with 6 digit LCD readout. These aluminum housing meters are available with factory and field calibration.

    Nylon Turbine Meter for 0.3 to 3 GPM (1 to 10 LPM). LCD readout. Displays gallons and liters. Field replaceable batteries. Factory and Field Calibration. 1 inch NPT. 150 PSIG/ 10.3 bar. 1.0 lbs., 0.5 kg.

  • Product Image- Electronic Digital Turbine Flowmeters

    Designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. "A1 Meters" are not field serviceable like the popular G2 Series Meters. For flowmeters with advanced features and additional housing materials, refer to the G series, G2 Series, GM Series or TM Series catagories. 

    • Accuracy: Percentage of Reading (Attainable only when used within stated flow ranges)
    • Repeatability: 0.5%
    • Factory Calibration- Non-Viscous Fluids: ± 1.5%
    • Linearity: ± 3.0%
    • User (Field) Calibration - Viscous Fluids: ± 1.0%, Non-viscous Fluids: ± 0.5% (Attainable only with proper calibration measurement sample.)
    • Operating Temp: 14°F to 140°F

  • gpiG2Alum

    • Accuracy: Percentage of Reading (Attainable only when used within stated flow ranges)
    • Repeatability: 0.5%
    • Factory Calibration- Non-Viscous Fluids: ± 1.5%
    • Linearity: ± 3.0%
    • User (Field) Calibration - Viscous Fluids: ± 1.0%, Non-viscous Fluids: ± 0.5% (Attainable only with proper calibration measurement sample.)
    • Operating Temp: 14°F to 140°F

  • gpiWirelessTanRec

    Discontinued No Repacement At This Time.......

    GPI's new, battery-powered Wireless Transmitter is designed to transmit flowrate from G2/A2 Series meters to the Receiver. This system includes both the Transmitter and Receiver. The Wireless Transmitter is perfect in many plant applications. Both Transmitter and Receiver are color coded making installation easy for optimum signal transmission.

    • Kit Includes: Transmitter to fit to G2/A2, Receiver includes 25 feet cable, Transmitter Battery Pack
    • Transmission Frequency: 903.37 MHz-921.37 MHz
    • Power Supply: Transmitter: Battery Pack (2 each) 3/4 AA Lithium (3.6V each - 7.2V total), Receiver: 5 VDC - 35 VDC
    • Signal: Transmitter: Delayed Burst Transmission Method, Receiver: Open Collector (Current Sinking), Max. OFF Voltage: 60V, Max. ON Voltage: 200 mA
    • Transmission Distance: 300 ft. Maximum; Line of Sight
    • Available Channels: Eight
    • Transmission Time Intervals: Four (1 sec., 2 sec., 5 sec., 10 sec.)
    • Enclosure: NEMA4

  • gpiG2PVDF

    The 1“ PVDF flowmeter was developed to target the aggressive chemical market. The meter is constructed of PVDF and Ceramic, both of which have excellent chemical compatibility. We have also incorporated true union fittings, that use Viton O-Rings, in the meter design. The fittings are available in NPT and ISO versions.

    • Linear Flow rate: 5 to 50 GPM
    • Repeatability: 0.3%
    • PVC - Ceramic - PVDF, Wetted: PVDF - Ceramic - PVDF
    • Accuracy: ± 1.5% of reading
    • Maximum Pressure: 150 PSI
    • Max. Pressure Drop: 11 PSIG
    • Operating Temp: 14 to 140°F (with Computer Electronics), 40 to 180°F (Housing only)
    • Dimensions: 8” L x 2.75” W x 3” H.

  • gpi_GAseries

    Output can be simple totals, rate of flow and various types of signal output.

    GPI Elctronics can be mounted to the meter or to a remote location and come with or without display.

  • gpiIMgroup

    GPI's IM36 is designed to provide accurate, simple flow measurement in a variety of applications.

    Applications include irrigation, HVAC (Hot & Chilled water), water distribution, municipal and industrial water and waste water. The stainless and PVDF construction makes it ideal for batching and blending of many industrial chemicals.

    • Stainless Steel Construction.
    • Line Sizes 1 1/2" to 36" in Diameter.
    • Cost effective. .

  • gpi

    Indicates Flow rate; 2 Totals (1 Accumulative, 1 Batch); 3 Calibrations (2 Factory -Factory calibrated to thin and medium viscosity’s and 1 field calibration., 1 Field) 2 to 20 GPM; reads in gallons; 1 in. NPT thread; female inlet, male outlet.

    • Simple, small and sturdy Electronic Digital Disc Meter with rugged PBT housing.
    • Mount on the end of a hose or a pipe, in-line.
    • Complete meter, including disc assembly, microprocessor and LCD readout.
    • Choice of gallon and liter measurement.
    • Factory calibrated for thin and medium fluids. Field calibrate for more viscous fluids.

  • Plastomatic Options

    Transmitter choice depends on numerous variables:

    • Do you need a Pulse out or 4-20 mA Transmitter?
    • Does you application require Remote Mounting or Local Mounting?
    • Do you need a Transmitter with or without Display?

  • gpiLubeMeter

    These new Lube Meters are ideal for use with..........

    • Engine Oils
    • Transmission Fluids
    • Antifreeze

    (Maximum Viscosity SAE 140)

  • gpiQMP

    The QMP is the portable QStar Ultrasonic flowmeter model. The use of multiple processors working in parallel means that QStar achieves an extremely high measurement rate.

    Signal processing takes place in high performance DSPs which are extremely precise and operate at very high resolution. This enables the device to achieve internal resolution of under 0.001 m/s flow velocity. Since the transit time measurement is purely digital, the measurement electronics are virtually drift and calibration-free.

    View Video;  http://www.youtube.com/watch?v=ZoOkvYkqsok&utm_source=processingUFM&utm_medium=email&utm_campaign=qstarUFM

  • gpiQMEfixed

    The QME is the energy-measuring fixed QStar Ultrasonic flowmeter model.

    The use of multiple processors working in parallel means that QStar achieves an extremely high measurement rate. Signal processing takes place in high performance DSPs which are extremely precise and operate at very high resolution. This enables the device to achieve internal resolution of under 0.001 m/s flow velocity. And since the transit time measurement is purely digital, the measurement electronics are virtually drift and calibration-free. This Unit Includes the Temperature Sensor

    View Video: http://www.youtube.com/watch?v=ZoOkvYkqsok&utm_source=processingUFM&utm_medium=email&utm_campaign=qstarUFM

  • gpiQMEfixed

    The QMF is the fixed QStar Ultrasonic flowmeter model.

    The use of multiple processors working in parallel means that QStar achieves an extremely high measurement rate. Signal processing takes place in highperformance DSPs which are extremely precise and operate at very high resolution. This enables the device to achieve internal resolution of under 0.001 m/s flow velocity. And since the transit time measurement is purely digital, the measurement electronics are virtually drift and calibration-free.

    View Video: http://www.youtube.com/watch?v=ZoOkvYkqsok&utm_source=processingUFM&utm_medium=email&utm_campaign=qstarUFM

  • gpiQMP